Home About Us Company Performance Product Overview Technical services Recruitment Leave a message Contact Us
Technical Specifications
Technical services
Selection Method
Technical Specifications

   The products are serial mass flow meters type of KLB-CMFI-DNXX. Products specs are divided from eight based on nominal line sizes: DN1, DN2, DN3, DN6, DN10, DN15, DN25, DN40, DN50, DN80, DN100 and DN150 (units: mm).

Technical Specifications

Titles

Technical Specifications

Mass flow accuracy

±[0.2% + ( zero stability /flow rate×100% ) ]

Mass flow repeatability

±(1/2) ×[0.2% + ( zero stability /flow rate×100% ) ]

Density range

0.2 g /cm 3 ~ 3.5g /cm 3

Density accuracy

± 0.002g /cm 3

Temperature range

-60℃ ~ + 200℃

Temperature accuracy

± 1℃

Output of current loop

4mA ~ 20mA

Output of frequency/pulse

0Hz ~ 10kHz

Contactor capacity of a Batch Control relay

24V/ 0.1A

Contactor form

normal open (would be changed to normal close while special order)

Specifications

Specs

Line Sizes (mm)

Flow Range (t/h)

Max. Tube Pressure (MPa)

Zero Stability (t/hr)

Velocity Parameter (h m/t s)

DN1
1
0 ~ 0.04
30.0
0.00001
353.68
DN2
2
0 ~ 0.16
30.0
0.00004
88.419
DN3
3
0 ~ 0.35
30.0
0.00008
39.298

DN6

6

0 ~ 0.7

30.0

0.00016

19.649

DN10

10

0 ~ 1.2

30.0

0.0002

4.9122

DN15

15

0 ~ 6.4

4.0

0.0011

2.1832

DN25

25

0 ~ 16

4.0

0.002

0.9022

DN40

40

0 ~ 40

4.0

0.003

0.3343

DN50

50

0 ~ 65

4.0

0.006

0.1965

DN80

80

0 ~ 160

2.5

0.01

0.0873

DN100
100
0 ~ 250
2.5
0.015
0.0544

DN150

150

0 ~ 550

2.5

0.03

0.0234

 

Specifications

Environmental Specifications

Medium

Liquid (include slurry, mixed with solid and so on)

Temperature of environment

0℃~+40℃

Temperature of medium

-60℃~+200℃

Density of medium

0.2 g/cm3~3.5g/cm3
Density accuracy ±0.002g/cm3

Pressure on operation

≤4.0MPa ( ≤30MPa )

Atmospheric pressure

86~106 kPa

Humidity of environment

≤90% RH

 

Sensor of Mass Flow Meter

Type

KLB-CMFI-DNXX

Precision grade

0.2

Material of inner tube

316L stainless steel

Join form

Flange or screw

Explosion proof identification code

ExibIIBT4Gb or ExdibIICT6Gb

 

Transmitter of Mass Flow Meter

Type

KLB-CMF I

Output signal

4~20mA, 0~10KHz, RS-485

Power supply

DC24V or AC220V±10%/50Hz±5%,
Power consumed <15W

Form of Explosion-proof

Essential safety or Composite

Display

Instant flow and gross, temperature,
density or concentration and so on

Batch Control relay

Contactor capacity: 24V/0.1A
Contactor form: normal open (would be changed
to normal close while special order)

Dimensions

tt
yy

Dimensions

Spec

Line sizes
(mm)

Fitting Options (mm)

Number and Hole Diameter of Flange join or Screw join (mm)

Weight(kg)

A

B

C

D

DN1
1
214
212
70
(237)
M16×1.5 Iner Screw join
6.3
DN2
2
214
221
70
(277)
M16×1.5 Iner Screw join
6.7
DN3
3
214
234
70
(329)
M16×1.5 Iner Screw join
7.0

DN6

6

214

234

70

(329)

M16×1.5 Iner Screw join

7.0

DN10

10

260

288

73

(364)

M20×1.5 Iner Screw join

9.5

DN15

15

379

479

90

φ65

4-φ14

14.5

DN25

25

472

528

9

φ85

4-φ14

18.0

DN40

40

522

623

116

φ110

4-φ18

26.0

DN50

50

597

689

137

φ125

4-φ18

34.0

DN80

80

650

839

175

φ160

8-φ18

53.7

DN100

100

714

942

198

φ190

8-φ22

68.5

DN150

150

815

1133

265

φ250

8-φ26

130.0

Copyright: Beijing Kelibo Instrument Co.Ltd